Sensitivity: The minimum detectable dose of HIV-1 p24 was determined to be approximately 15.6 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 15.6 pg/ml
Sensitivity: The minimum detectable dose of Human IL12B / IL-12B was determined to be approximately 15.625 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 15.625 pg/ml
Sensitivity: The minimum detectable dose of Human Interleukin-32 / IL-32 was determined to be approximately 23.4375 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 23.4375 pg/ml
Sensitivity: The minimum detectable dose of Human IFN gamma / IFNG was determined to be approximately 78.125 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 78.125 pg/ml
Sensitivity: The minimum detectable dose of Human TREM-2 / TREM2 was determined to be approximately 125 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 125 pg/ml
Sensitivity: The minimum detectable dose of H7N9 ( A/Shanghai/1/2013 ) HA was determined to be approximately 62.5 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 62.5 pg/ml
Sensitivity: The minimum detectable dose of Mouse CD5L was determined to be approximately 6.25 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 6.25 pg/ml
Sensitivity: The minimum detectable dose of Cynomolgus CD200R was determined to be approximately 62.5 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 62.5 pg/ml
Sensitivity: The minimum detectable dose of H3N2 (A/Brisbane/10/2007) HA was determined to be approximately 625 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 625 pg/ml
Seit 1971 dient der ELISA dem Nachweis und oder der Konzentrationsbestimmung von Proteinen, eines Analytgemisches, niedermolkularer Verbindungen (zb. Toxine, Hormone) oder Viren.
Der ELISA beruht auf einem Antikörper-Antigen-Nachweis. Grundlage hierbei ist, dass entweder Antigen oder Antikörper auf einer Multiwell-Platte (z. aus Polystyrol) immobilisiert werden und das nachzuweisende Analyt im Folgeschritt gebunden wird.
Die Antigene werden über Wasserstoffbrückenbindungen, ionische und hydrophobe Wechselwirkungen und Van-der-Waals-Kräfte von den Antikörpern gebunden. Dabei erfolgt diese Bindung nach dem Schlüssel-Schloss-Prinzip und ist sehr spezifisch. Die verwendeten Antikörper können dabei Monoklonal (mAb) oder Polyklonal sein. Monoklonale Antikörper werden aus Hybridoma-Zellen, einer Fusion aus Krebszelle (Myelomazelle) und antikörperproduzierender Zelle (B-Zelle) hergestellt und binden selektiv ein spezifisches Epitop auf dem Antigen. Polyklonale Antikörper sind ein Gemisch verschiedener Antikörper, die verschiedene Epitope auf dem Antigen erkennen. Nach erfolgreicher Bindung erfolgt der Nachweis in der Regel kolorimetrisch.
Dabei kommt es nach erfolgreicher Antigen-Antikörper-Bindung und Zugabe eines Substrates zu einem Farbumschlag in der Mikrotiterplatte, welches durch ein Enzym katalysiert wird, das zuvor mit dem Antikörper oder Antigen konjugiert wurde.
Für weitere Informationen steht Ihnen unsere Infothek jederzeit zur Verfügung.
Filtern nach
Filtern nach:
Specific Against:
Influenza
Rat
Hersteller:
MyBioSource
Analytik Jena
Cytoskeleton
ICL
Lifespan Technologies
Sino Biological