Sensitivity: The minimum detectable dose of Human C-Reactive Protein / CRP was determined to be approximately 46.88 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 46.88 pg/ml
Sensitivity: The minimum detectable dose of H4N6 (A/mallard/Ohio/657/2002) HA was determined to be approximately 109.38 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 109.38 pg/ml
Sensitivity: The minimum detectable dose of HIV-1 p24 was determined to be approximately 15.6 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 15.6 pg/ml
Sensitivity: The minimum detectable dose of Human IL12B / IL-12B was determined to be approximately 15.625 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 15.625 pg/ml
Sensitivity: The minimum detectable dose of Human Interleukin-32 / IL-32 was determined to be approximately 23.4375 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 23.4375 pg/ml
Sensitivity: The minimum detectable dose of Human IFN gamma / IFNG was determined to be approximately 78.125 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 78.125 pg/ml
Sensitivity: The minimum detectable dose of Human TREM-2 / TREM2 was determined to be approximately 125 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 125 pg/ml
Sensitivity: The minimum detectable dose of H7N9 ( A/Shanghai/1/2013 ) HA was determined to be approximately 62.5 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 62.5 pg/ml
Sensitivity: The minimum detectable dose of Mouse CD5L was determined to be approximately 6.25 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 6.25 pg/ml
Sensitivity: The minimum detectable dose of Cynomolgus CD200R was determined to be approximately 62.5 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 62.5 pg/ml
Sensitivity: The minimum detectable dose of H3N2 (A/Brisbane/10/2007) HA was determined to be approximately 625 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 625 pg/ml
ELISA-Sets bieten dir den größtmöglichen Spielraum für die Gestaltung Ihres ELISA-Tests. Diese Sets beinhalten sowohl den Fänger- als auch den Detektionsantikörper, Standards und notwendige Substrate für die Detektion. Dabei bleibt die Beschichtung der Polystyrol Multiwell Platte ganz dir überlassen. Ist dieser „Coating“-Schritt vollzogen, kann die zu untersuchende Probe auf die Polystyrol Multiwell Platte gegeben werden, sodass das Analyt von Fängerantikörper gebunden werden kann. Der im Set zur Verfügung gestellte Detektionsantikörper kann danach zum Nachweis des Analyts, durch Fluoreszenz, Chemielumineszenz oder einen Farbumschlag, genutzt werden.
Ausführliche Informationen zum Thema ELISA stehen dir in unserer Infothek zur Verfügung.