Sensitivity: The minimum detectable dose of Rhesus CD32a / Fc gamma RIIA / FCGR2A was determined to be approximately 7.8 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 7.8 pg/ml
Sensitivity: The minimum detectable dose of HIV-1 gp120 / Glycoprotein 120 was determined to be approximately 39.06 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 39.06 pg/ml
Sensitivity: The minimum detectable dose of Human HER2 / ErbB2 / CD340 was determined to be approximately 24 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 24 pg/ml
Sensitivity: The minimum detectable dose of Rhesus CD16 / FCGR3 was determined to be approximately 12.5 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 12.5 pg/ml
Sensitivity: The minimum detectable dose of Human CD69 was determined to be approximately 15.6 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 15.6 pg/ml
Sensitivity: The minimum detectable dose of Human SIGLEC5 was determined to be approximately 234.38 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 234.38 pg/ml
Sensitivity: The minimum detectable dose of Human IL3RA / CD123 was determined to be approximately 31.25 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 31.25 pg/ml
Sensitivity: The minimum detectable dose of Human CD160 was determined to be approximately 93.75 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 93.75 pg/ml
Sensitivity: The minimum detectable dose of Human CD84 was determined to be approximately 156.25 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 156.25 pg/ml
Sensitivity: The minimum detectable dose of Human PTX3 / Pentraxin 3 / TSG-14 was determined to be approximately 24 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 24 pg/ml
Sensitivity: The minimum detectable dose of human SerpinG1 / C1IN was determined to be approximately 78.125 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 78.125 pg/ml
Sensitivity: The minimum detectable dose of human EpCAM / TROP1 was determined to be approximately 46.8 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 46.8 pg/ml
Sensitivity: The minimum detectable dose of Human OSMR / IL-31RB was determined to be approximately 234.4 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 234.4 pg/ml
Sensitivity: The minimum detectable dose of human CD40 / TNFRSF5 was determined to be approximately 3.9 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard Detection: 3.9 pg/ml
ELISA-Sets bieten dir den größtmöglichen Spielraum für die Gestaltung Ihres ELISA-Tests. Diese Sets beinhalten sowohl den Fänger- als auch den Detektionsantikörper, Standards und notwendige Substrate für die Detektion. Dabei bleibt die Beschichtung der Polystyrol Multiwell Platte ganz dir überlassen. Ist dieser „Coating“-Schritt vollzogen, kann die zu untersuchende Probe auf die Polystyrol Multiwell Platte gegeben werden, sodass das Analyt von Fängerantikörper gebunden werden kann. Der im Set zur Verfügung gestellte Detektionsantikörper kann danach zum Nachweis des Analyts, durch Fluoreszenz, Chemielumineszenz oder einen Farbumschlag, genutzt werden.