Sensitivity: The minimum detectable dose of Rat LIFR / CD118 was determined to be approximately 39.06 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 39.06 pg/ml
Sensitivity: The minimum detectable dose of Rat IL-1R1 / CD121a was determined to be approximately 62.5 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 62.5 pg/ml
Sensitivity: The minimum detectable dose of Rat Beta-2 microglobulin / B2M was determined to be approximately 2.66 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 2.66 pg/ml
Sensitivity: The minimum detectable dose of Rat MMP9 / MMP-9 / CLG4B was determined to be approximately 19.53 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 19.53 pg/ml
Sensitivity: The minimum detectable dose of Rat CD86 / B7-2 was determined to be approximately 4.7 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 4.7 pg/ml
Sensitivity: The minimum detectable dose of Rat ACE2 / Angiotensin-Converting Enzyme 2 was determined to be approximately 125 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 125 pg/ml
Sensitivity: The minimum detectable dose of Rat CD93/C1qR was determined to be approximately 15.625 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 15.625 pg/ml
Sensitivity: The minimum detectable dose of Rat LILRA5 was determined to be approximately 7.81 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 7.81 pg/ml
Sensitivity: The minimum detectable dose of Rat Coagulation Factor III / Tissue Factor / CD142 was determined to be approximately 23.45 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 23.45 pg/ml
Sensitivity: The minimum detectable dose of Rat VEGF / VEGFA was determined to be approximately 23.44 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. Detection: 23.44 pg/ml
ELISA-Sets bieten dir den größtmöglichen Spielraum für die Gestaltung Ihres ELISA-Tests. Diese Sets beinhalten sowohl den Fänger- als auch den Detektionsantikörper, Standards und notwendige Substrate für die Detektion. Dabei bleibt die Beschichtung der Polystyrol Multiwell Platte ganz dir überlassen. Ist dieser „Coating“-Schritt vollzogen, kann die zu untersuchende Probe auf die Polystyrol Multiwell Platte gegeben werden, sodass das Analyt von Fängerantikörper gebunden werden kann. Der im Set zur Verfügung gestellte Detektionsantikörper kann danach zum Nachweis des Analyts, durch Fluoreszenz, Chemielumineszenz oder einen Farbumschlag, genutzt werden.
Ausführliche Informationen zum Thema ELISA stehen dir in unserer Infothek zur Verfügung.
Filtern nach
Filtern nach:
Specific Against:
Deer
Rat
Salmon
Turkey
Pan-species
Hersteller:
Abbexa
MyBioSource
Cusabio
FineTest
GenScript
Raybiotech
Sino Biological