Profile Informations
Login Datas
or login
Biomatik
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Actin Alpha 1, Skeletal Muscle (ACTa1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Actin Alpha 1, Skeletal Muscle (ACTa1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Actin Alpha 1, Skeletal Muscle (ACTa1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Actin Alpha 1, Skeletal Muscle (ACTa1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.Research area:Developmental science; Bone metabolism;
Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat), Oryctolagus cuniculus (Rabbit), Sus scrofa; Porcine (Pig), Bos taurus; Bovine (Cattle)
This assay has high sensitivity and excellent specificity for detection of Actin Alpha 1, Skeletal Muscle (ACTa1). No significant cross-reactivity or interference between Actin Alpha 1, Skeletal Muscle (ACTa1) and analogues was observed.
Actin Alpha 1, Skeletal Muscle
ACT-A1; ASMA; CFTD; CFTD1; CFTDM; MPFD; NEM1; NEM2; NEM3
0.57 ng/mL
1.56-100 ng/mL
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Tissue homogenates, cell lysates, cell culture supernates and other biological fluids
1x96, 5x96 and 10x96 Wells
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Actin Alpha 1, Skeletal Muscle (ACTa1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Actin Alpha 1, Skeletal Muscle (ACTa1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
3 hours
Storage: -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.Expiry Date: 8 monthsStability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.Shipping Condition: Blue ice
SandwichDetection Method: Colorimetric
For research use only. Not for diagnostic procedures.Precaution of Use: The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
Brand | Biomatik |
---|---|
Country of Manufacture | USA |
Sensitivity | 0.57 ng/mL |
Antigen Name | Actin Alpha 1, Skeletal Muscle |
Detection Range | 1.56-100 ng/mL |
Certified | ISO 9001 and ISO 13485 |
Alias | ACT-A1; ASMA; CFTD; CFTD1; CFTDM; MPFD; NEM1; NEM2; NEM3 |