Profile Informations
Login Datas
or login
Biomatik
Research area Metabolic pathway; Tumor immunity; Infection immunity; Endocrinology; Hematology; Hepatology;
Multispecies (General)
This assay has high sensitivity and excellent specificity for detection of 8-Hydroxydeoxyguanosine (8-OHdG). No significant cross-reactivity or interference between 8-Hydroxydeoxyguanosine (8-OHdG) and analogues was observed.
8-Hydroxydeoxyguanosine
8OHdG; 7,8-Dihydro-8-Oxo-2'-Deoxyguanosine; 7,8-Dihydro-8-Oxodeoxyguanosine; 8-Hydroxy-2'-Deoxyguanosine; 8-Oxo-DG
26.29 pg/mL
74.07-6000 pg/mL
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Serum, plasma and other biological fluids
1x96, 5x96 and 10x96 Wells
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 8-Hydroxydeoxyguanosine (8-OHdG) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 8-Hydroxydeoxyguanosine (8-OHdG) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
2 hours
Storage: -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.Expiry Date: 8 monthsStability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.Shipping Condition: Blue ice
CompetitiveDetection Method: Colorimetric
For research use only. Not for diagnostic procedures.Precaution of Use: The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
Brand | Biomatik |
---|---|
Country of Manufacture | USA |
Sensitivity | 26.29 pg/mL |
Antigen Name | 8-Hydroxydeoxyguanosine |
Detection Range | 74.07-6000 pg/mL |
Certified | ISO 9001 and ISO 13485 |
Alias | 8OHdG; 7,8-Dihydro-8-Oxo-2'-Deoxyguanosine; 7,8-Dihydro-8-Oxodeoxyguanosine; 8-Hydroxy-2'-Deoxyguanosine; 8-Oxo-DG |