Profile Informationen
Login Daten
oder Einloggen
Sino Biological
For the quantitative determination of Human ALK-1 / ACVRL1 concentration in serum.
Human
Ten serum samples from apparently healthy people were evaluated for the presence of ALK1 in this assay.The average concentration of four detected samples is 0.57 ng/mL. Other samples measured less than the lowest ALK1 standard, 31.25 pg/mL.
This assay recognizes both recombinant and natural human ALK1. The factors listed below were prepared at 50 ng/mL in dilution buffer and assayed for cross-reactivity. No cross-reactivity was observed.
ACVRL1Antigene: 10066-H08Hcapture antibody type: rabbit mAbdetection antibody type
CD48 / SLAMF2
18.8 pg/ml
31.25-2000 pg/ml
ISO9001-2008
96 Wells
Unopened Kit: Store at 2 - 8°C
Opened/Reconstituted Reagents: Please refer to CoA
Solid Phase Sandwich ELISA
1. 96 well microplate coated with Capture Antibody
2. Detection Antibody conjugated to HRP
3. Standards
4. Wash Buffer Concentrate
5. Dilution Buffer Concentrate
6. Color Reagent A
7. Color Reagent B
8. Stop Solution
Menge | 96 Wells |
---|---|
Hersteller | Sino Biological |
Herstellerland | China |
Sensitivity | 18.8 pg/ml |
Specific Against | Human |
Antigen Name | ALK-1 |
Detection Range | 31.25-2000 pg/ml |
Zertifikat | ISO9001-2008 |
Alias | ALK-1 / ACVRL1 |